OSHA'S HAZARD COMMUNICATION STANDARD
U.S. DEPARTMENT OF LABOR
29 CFR 1910.1200 OMB NO: 1218-0072
IDENTITY NO: PP1659,PP1659-1 NAME: HARD SURFACE POLISH PROTECTOR
SECTION 1
MANUFACTURER'S/SHIPPER'S NAME: IPT, INC.
ADDRESS: 4216 N. Pecos Road, Suite 102 PHONE: (702) 895-9865
CITY: LAS VEGAS STATE: NEVADA CONTACT: TOM COX
DATE PREPARED: 4/15/02 EMERGENCY PHONE (CHEMTREC): (800) 424-9300
SECTION 2 - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION
HAZARDOUS COMPONENTS CAS# OSHA PEL ACGIH TLV WEIGHT %
PETROLEUM NAPHTHA 64741657 100 PPM 100 PPM N/A
MORPHOLINE 110918 20 PPM 20 PPM 7mmHG@20 C
SODIUM NITRITE 7632-00-0 N/A N/A
A-46 cONSISTING OF 20% NONE N/A 1000 PPM 46 PSI@70 F
PROPANE (19%) 74-98-6
ISOBUTANE (81%) 75-28-5 N/A 800 PPM
SECTION 3 - PHYSICAL/CHEMICAL CHARACTERISTICS
BOILING POINT: 100 F EVAPORATION RATE: (n-Butyl Acetate=1)>1
% VOLATILE VOLUME: N/A VAPOR DENSITY: HEAVIER THAN AIR
WEIGHT PER GALLON (C0NC): 7.17 LB SOLUBILITY IN WATER: MISIBLE
APPEARANCE AND ODOR: COLORLESS/SOLVENT ODOR
SECTION 4 - FIRE AND EXPLOSION HAZARD DATA
FLASH POINT OF CONCENTRATE: 145 F FLAMMABLE LIMITS: NOT TESTED
LEL: NOT TESTED UEL: NOT TESTED
pH: NOT TESTED DOT#: ORM-D
NFPA HAZARD RATING H F R S
(O=LEAST, 4=EXTREME) 2 2 0 0
EXTINGUISHING MEDIA: CO2, FOAM, WATER FOG, DRY CHEMICALS
SPECIAL FIRE FIGHTING PROCEDURES: WEAR SELF-CONTAINED BREATHING APPARATUS WITH FULL FACE
PIECE OPERATED IN PRESSURE-DEMAND MODE WHEN FIGHTING FIRES. WATER MAY BE USED ON CONTAINERS
EXPOSED TO INTENSE HEAT TO COOL THEM AND PREVENT VAPOR PRESSURE BUILDUP WHICH COULD RESULT
IN CONTAINER RUPTURE. IF AEROSOL CONTAINERS BURST, STAY CLEAR UNTIL BURSTING IS COMPLETED.
AEROSOLS CAN BE PROJECTILES IF BURSTING.
UNUSUAL FIRE AND EXPLOSION HAZARDS: AEROSOLS MAY BURT AT TEMPERATURES ABOVE 120 F. PRODUCT
IS FLAMMABLE UNDER EXPLOSIVE CONDITIONS. KEEP AWAY FROM IGNITION SOURCE/OPEN FLAMES.
SECTION 5 - REACTIVITY DATA
STABILITY: STABLE
CONDITIONS TO AVOID: OPEN FLAME OR MEANS WHICH CAUSE HIGH TEMPERATURE
INCOMPATIBLE MATERIALS TO AVOID: STRONG OXIDIZERS
HAZARDOUS DECOMPOSITION OR BYPRODUCTS: CARBON MONOXIDE/DIOXIDE
HAZARDOUS POLYMERIZATION: NONE
SECTION 6 - HEATH HAZARD DATA
ROUTES OF ENTRY:
INHALATION: POSSIBLE INGESTION: POSSIBLE
SKIN: POSSIBLE HEALTH HAZARDS: SAME SIGNS & SYMPTOMS OF EXPOSURE
OSHA CARCINOGENICITY: NONE NTP: NONE IARC MONOGRAPHS: NONE
SIGNS & SYMPTOMS OF OVER EXPOSURE:
EYES: BURNING, IRRITATION SKIN: IRRITATION, DRYNESS, CRACKING
INGESTION: NAUSEA, IRRITATION INHALATION: IRRITATION, DROWSINESS
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: SAME AS SIGNS & SYMPTOMS OF
OVER EXPOSURE.
EMERGENCY FIRST AID PROCEDURES:
EYES: FLUSH WITH WATER FOR 15 MINUTES. IF IRRITATION PERSISTS CALL PHYSICIAN.
SKIN: WASH WITH SOAP AND WATER. IF IRRITATION PERSISTS CALL PHYSICIAN.
INGESTION: DO NOT INDUCE VOMITING, CALL PHYSICIAN
INHALATION: MOVE PERSON TO FRESH AIR. IF UNCONSCIOUS CALL PHYSICIAN
SECTION 7 - PRECAUTIONS FOR SAFE HANDLING AND USE
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: SOAK UP WITH INERT,
ABSORBENT MATERIAL AND PLACE IN A PROPER WASTE DISPOSAL CONTAINER.
WASTE DISPOSAL METHOD: DISPOSE OF IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS.
PRECAUTIONS TO BE TAKEN IN HANDLING & STORING: STORE IN COOL,DRY PLACE. OUT OF DIRECT
SUNLIGHT.
OTHER PRECAUTIONS: KEEP OUT OF REACH OF CHILDREN. FOLLOW DIRECTIONS ON THE
CONTAINER FOR PROPER USE OF THIS PRODUCT. KEEP AWAY FROM HEAT AND FLAME.
SECTION 8 - CONTROL MEASURES
RESPIRATORY PROTECTION: OPEN ALL DOORS & WINDOWS. EXPOSURES ABOVE THE TLV OR PEL
REQUIRE A NOISH APPROVED RESPIRATOR EQUIPPED FOR THE EXPOSURE OR SUITABLE
RESPIRATORY PROTECTION PER 29 CFR 1910-134.
VENTILATION: LOCAL EXHAUST: IF AVAILABLE SPECIAL: NONE
MECHANICAL: IF AVAILABLE OTHER: NONE
PROTECTIVE GLOVES: RUBBER, PLASTICS
EYE PROTECTION: GLASSES, GOGGLES
OTHER PROTECTIVE CLOTHING OR EQUIPMENT: NONE
WORK HYGIENIC PRACTICES: USE COMMON SENSE AND CARE AROUND CHEMICALS. NEVER MIX
CHEMICALS. CONSULT SUPERVISOR FOR OTHER PRACTICES. ALL PRACTICES DEPEND ON YOUR
SPECIFIC BUSINESS. DIRECTIONS FOR USE ARE NORMALLY FOUND LABEL, WHICH WILL DICTATE
ENGINEERING & CONTROL MEASURES.
OTHER SPECIAL REQUIREMENTS: NONE